leisure
Premier Inn, Basingstoke
Value
£4.5 million
Client
Fishron Developments
Rating
Very Good
About the project
New build hotel to Premier Inn Developer Specification, including VRV heating/cooling and hot water pre-heat. The Tenants requirement is a BREEAM ‘VERY GOOD’ rating.
Understanding the challenges
The MEP services engineering solution included VRF heating and cooling with heat recovery, MVHR ventilation, kitchen ventilation to BESA DW172, domestic hot water heat pump heating, low energy lighting, power distribution, access control, CCTV, lightning protection, above ground drainage with grey water recycling and photovoltaic panels.
Want to find out more or discuss your project?